Tesla Model S: Disconnect 12V Power (RWD)
Warning: If the 12V power supply is disconnected, do
not attempt to open any doors with door glass in closed position.
Failure to follow this instruction could result in door glass
shatter.
Note: Before disconnecting the 12V power supply,
ensure that the driver's door window is fully open. Failure to
follow this instruction could result in vehicle lockout.
Disconnect
- Open the front trunk.
- Turn off the climate control system.
- Fully open the driver's window.
- Close all doors.
- Remove the particulate filter (refer to procedure).
- Remove the rivets (x3) that secure the cowl screen panel to the
body.
- Gain access to the particulate filter housing.
- Remove the bolts (x2) that secure the pollen filter front
housing to the HVAC duct (torque 1.5 Nm). Release the tabs (x2) to
remove the front housing.
Note: RHD vehicles have a 1-piece pollen filter
housing. Remove the nuts (x3), then remove the housing.
Warning: If the 12V power supply is disconnected, do
not attempt to open any doors with door glass in closed
position. Failure to follow this instruction could result in
door glass shatter.
Note: Before disconnecting the 12V power supply,
ensure that the driver's door window is fully open. Failure to
follow this instruction could result in vehicle lockout.
- Disconnect the 12V battery ground connection (torque 5 Nm).
- Disconnect the first responder loop (X536). Do not cut the loop.
- Wait at least 2 minutes for all electrical circuits to fully
discharge.
Warning: Before working on any high voltage
components, perform the Electrical Isolation Procedure (refer to procedure).
Connect
Note: Connect is reverse of disconnect, except for the
following:
- For RHD vehicles, install the top 2 pollen filter housing
nuts before installing the lower nut.
READ NEXT:
Warning: If the 12V power supply is disconnected, do
not attempt to open any doors with door glass in closed position.
Failure to follow this instruction could result in door glass
shat
Warning: If the 12V power supply is disconnected, do
not attempt to open any doors with door glass in closed position.
Failure to follow this instruction could result in door glass
shat
Warning: If the 12V power supply is disconnected, do
not attempt to open any doors with door glass in closed position.
Failure to follow this instruction could result in door glass
shat
SEE MORE:
Warning: To avoid personal injury, eye protection must
be worn when performing this operation.Warning: To avoid personal injury, safety-toe shoes and
cut-resistant gloves are recommended when performing this
operation.
Note: A demonstration video for removing and
r
Removal
Remove glove box assembly (refer to procedure)
Depress clip and remove clevis pin securing damper module to
glove box assembly.
Rotate module counter-clockwise and release from glove box.